Skip to main content

OT security with context for industrial networks

Understand observed events alongside affected devices, connections and operational processes.

Capability, tests and availability

Implemented foundation
Passive capture runtime, bounded classification and Windows adapter.
Documented test evidence
26 repository tests and physical home lab on 2026-10-08; not full protocol decoding.
Availability and production
Public simulation. Customer OT pilots, installation and operational acceptance remain separate.
  • PLS / PLC
  • HMI / SCADA
  • SPAN / TAP
  • Edge Connector

Practical example

Operations needs to understand changed communication without adding control paths into a critical facility.

What should be checked?

Agree ownership, mirror point and expected traffic. The observation model separates network metadata, verified device identity and operational decisions.

What should be recorded?
Scoped observation plan, zone map and operational approval.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

OT architecture

The local Edge Connector is the data plane; SaaS is the control plane. Observation grants no operational control.

  • Capture-NIC
  • Management-NIC
  • Local event store
  • Outbound control plane

Practical example

A sensor must tolerate lost cloud connectivity without moving mirrored raw traffic to a central fallback.

What should be checked?

Separate capture and management; keep raw data under local processing. SaaS is the control plane, not general remote administration or PLC-write permission.

What should be recorded?
Data flow, allowed outbound connections, storage boundaries and failure modes.
  1. Operations zone / PLC
  2. Approved SPAN / TAP
  3. Capture NIC
  4. Local classification
  5. Assessed OT context
Architecture sketch: raw traffic stays local. A separate management interface handles approved outbound control-plane traffic. No control commands back to PLCs.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Pumping stations and water

The fictional water scenario illustrates dependencies and continuity. It proves no customer pilot or actual incident.

  • Pump station
  • PLS
  • HMI
  • Rayvn

Practical example

At a fictional water facility, new traffic appears while pump-station telemetry remains uncertain.

What should be checked?

Assess redundancy, manual local operation, water delivery and decision authority. Hand over only bounded, assessed context to incident coordination.

What should be recorded?
Synthetic incident log, dependencies, contact roles and review points.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Siemens PLCs

PLC context helps explain affected zones. A connection does not verify programs, firmware or safe operation; the demo sends no PLC commands.

  • SIMATIC S7-1200 / S7-1500
  • TIA Portal
  • Engineering station

Practical example

An engineering station contacts a Siemens PLC outside maintenance. Traffic alone does not explain intent.

What should be checked?

Compare model, firmware, project owner, maintenance order and approved peers. This is a review method, not lab proof of Siemens program validation or download.

What should be recorded?
Device list, firmware basis, change order and OT-owner assessment.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Siemens · S7-1200 communication protocols and ports

Modbus TCP

The physical lab found TCP/502 candidates. Port classification does not prove full Modbus decoding or function-code coverage.

  • Modbus TCP
  • TCP/502
  • MBAP
  • Function codes

Practical example

A TCP/502 connection is observed. First establish whether expected Modbus traffic and process context explain it.

What should be checked?

Review client, server, direction and observation period. MBAP and function codes are application-layer concepts; current port candidates do not prove reads, writes or malicious commands.

What should be recorded?
203 TCP/502 candidates in the historical lab; no full semantic decoding.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Modbus Organization · specifications

OPC UA

Passive mirroring observes traffic. An OPC UA client establishes an active session or subscription requiring certificate, permission and sampling/load review.

  • OPC UA
  • SecureChannel
  • Certificates
  • Subscriptions

Practical example

A proposed OPC UA connection needs more than a visible TCP port in mirrored traffic.

What should be checked?

Review certificate trust, SecurityMode, user rights, sampling and subscription load. An active client can load the server; it differs from passive classification and is not production-validated here.

What should be recorded?
Proposed trust chain, read scope, performance budget and operational approval.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

OPC Foundation · Security Mode

S7 communication

TCP/102 alone confirms neither an S7 operation nor PLC authority. Classification, decoding and approved device changes are separate.

  • S7
  • ISO-on-TCP
  • TCP/102
  • PG / HMI

Practical example

TCP/102 between an HMI and controller may be expected, but a new peer needs review.

What should be checked?

Use the Siemens reference to understand ISO-on-TCP and document approved peers. Repository evidence does not establish a complete S7 decoder or engineering-operation verification.

What should be recorded?
Approved communication matrix and explicit decoder limitations.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Siemens · ISO-on-TCP / S7 communication

Fortinet and segmentation

Validate FortiGate/FortiSwitch firmware, rules and traffic paths. A diagram is not an approved segmentation design.

  • FortiGate
  • FortiSwitch
  • VLAN
  • IPSec

Practical example

A VPN connects facilities, but encryption does not determine which systems should communicate.

What should be checked?

Review zones, minimum traffic, return routes and logging. IPSec protects transport; segmentation rules and customer approval govern access. No automatic firewall changes run.

What should be recorded?
Zone/traffic matrix, tunnel scope, approved rules and post-change checks.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

SPAN and ERSPAN

SPAN mirrors locally; ERSPAN transports mirrored traffic. Review capacity, drops, MTU and jitter. The recorded lab used local mirroring, not production ERSPAN.

  • SPAN
  • ERSPAN / GRE
  • IPSec
  • MTU / jitter

Practical example

Mirrored traffic from a remote pump station needs transport without degrading the production link.

What should be checked?

ERSPAN encapsulates mirrored traffic in GRE; it does not itself encrypt it. Assess IPSec transport, MTU, fragmentation, queues and drops. The lab verified local SPAN, not this transport chain.

What should be recorded?
Capacity measurements, mirror direction, transport design and outage plan.
  1. Remote mirror point
  2. ERSPAN / GRE
  3. Assessed IPSec transport
  4. Local receiver
Transport concept for assessment, not a verified production ERSPAN test. Budget bandwidth and overhead; assess MTU, drops and outages before a pilot.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Fortinet · Mirror / ERSPAN

IETF · GRE / RFC 2784

Local Edge Connector

Separate capture and management interfaces. Bound frames, queues and memory; account for drops. Raw packets are not persisted or uploaded by the documented pipeline.

  • Windows
  • Npcap / dumpcap
  • Bounded queues
  • Local parsing

Practical example

Capture traffic spikes. The collector must expose losses instead of unbounded growth or false completeness.

What should be checked?

Repository contracts bound frames, queues and memory and record errors/drops. Verify a separate capture interface, timestamps and local processing before physical acceptance.

What should be recorded?
Adapter status, observed/parsed frames, drop counters and local data boundary.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Passive security controls

Measure CPU, bandwidth, jitter and loss before operational approval. Passive observation is not active scanning or device control; unknown coverage stays visible.

  • Freshness
  • Capacity
  • Protocol candidates
  • Zone review

Practical example

No alerts may mean quiet operations or a mirror that stopped supplying traffic.

What should be checked?

Check last observation, interface, expected source and capacity indicators. Review new peers and candidates against an approved baseline; unknown traffic is not automatically an attack.

What should be recorded?
Baseline, coverage gaps, interpretation basis and accountable review.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

Technical lab and tests

Distinguish automated fixtures, PCAP parsing and historical physical home-lab evidence from production validation.

  • Physical mirror
  • FortiOS 7.2.6
  • Vitest

Practical example

A lab report must separate observed measurements from desired future capacity.

What should be checked?

On 2026-10-08, 302 frames were observed, accepted and parsed; 203 were TCP/502 candidates and 99 unknown. Zero recorded drops applies to this run, not a lossless guarantee.

What should be recorded?
Dated home-lab receipt and separate runtime, classification and adapter tests.
Explore this in the product demo
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md

26/26 · 2026-11-19

Try the demonstration

Synthetic demonstration. No customer connection, production control or real messages. Pilots and integrations require separate validation.

  • OT-scenario
  • Water treatment
  • Rayvn handoff

Practical example

Follow the simulated PLC connection and see why observations need investigation before escalation.

What should be checked?

Start the incident scenario and compare observed and unresolved information. See operations, security and response share a case without PLC control.

What should be recorded?
Synthetic exercise with clear signal/confirmed-incident separation.
View sources and limitations

Examples are professional review suggestions, not customer incident reports or proof that every check ran. The lab receipt shows the actual test scope.

  • collector/otPassiveCaptureRuntime.pr664.test.ts
  • collector/otProtocolClassifier.pr665.test.ts
  • collector/windowsPhysicalOtCaptureAdapter.pr703.test.ts
  • docs/PHYSICAL-CONNECTOR-LAB-ACCEPTANCE-PR704.md
  • docs/OT-PROTOCOL-CLASSIFICATION.md
Try the demonstration

Further reading

Articles in Norwegian.

Book a demonstration